Livicom Smart Home

Livi CSM opening sensor manual

Description
The Livi CSM opening sensor (hereafter referred to as the sensor) is designed to control the opening and closing of structural elements such as doors, windows, shutters, hatches and gates.

The sensor switches to the alarm mode when the structural element is open:
  1. The indicator (3) blinks red once,
  2. The sensor sends an alert to the Livi Smart Hub (hereafter referred to as the hub).

The sensor consists of a magnetically operated switch (1) and a control element - a magnet (2).
Sensor appearance
Женщина-диспетчер ПЦН
  1. Magnetically operated switch
  2. Magnet
  3. Indicator
  4. Hole to access the binding mode button
  5. Mark for placing the magnet
  6. Battery
Binding to the hub
The sensor must be unpacked and allowed to reach room temperature for at least two hours before handling if it was transported or stored at low temperatures.
Only the owner of the site can bind the sensor to the hub. Make sure that the site guard is disabled and the hub is online.
Follow these steps to bind the sensor to the hub:

1. Insert a thin paper clip into the hole (4) in the device enclosure and press the binding mode button once.

The sensor indicator will start blinking blue.
Женщина-диспетчер ПЦН
2. In the Livicom app, open the "Devices" screen. In the upper right corner of the screen tap "+" and select "Add Device".

The system compiles a list of radio devices available for binding within the range of the hub radio channel.

3. Select the sensor from the list and check that its name and serial number in the app match the data on the sensor enclosure.

4. Tap CONTINUE and follow on-screen instructions in the app to bind the sensor to the hub.

The sensor indicator will blink green 5 times after successful binding.
Женщина-диспетчер ПЦН
You should choose whether the sensor will be installed on the front door of the site when binding the opening sensor to the hub.

Select NO if you do not use a Livi RFID control panel to enable / disable the guard of the site.

Select YES if you are going to use a Livi RFID control panel to enable / disable the guard of the site AND you are going to install the sensor on the front door of the site.

The answer YES impacts the way the full guard of the site will be enabled and disabled if the user uses the Livi RFID control panel. As the Livi RFID is usually installed inside the guarded site, users need some time to exit the site before the full guard will be enabled and to enter the site before the alarm will be triggered - the delay for entry / exit.

If the front door of the site is protected with a Livi CSM opening sensor, then:
  • the full guard will be enabled immediately after the user shuts the front door (even if the delay for exit is not over);
  • the delay for entry countdown will start at the moment the user opens the front door.
    Женщина-диспетчер ПЦН
    The sensor switches to the binding mode only for 60 seconds. If you have not bound it to the hub within this period, insert a thin paper clip into the hole in the sensor enclosure, press the button and hold it until the sensor indicator starts blinking blue. The sensor will switch to binding mode again.
    Replacing the battery
    1. Open the enclosure of the magnetically operated switch (1): insert a flat-blade screwdriver into the hole between the lid and the base of the enclosure, and flip off the lid by turning the flat-blade screwdriver left or right.
    2. Pull out the sensor board, using the flat-blade screwdriver to unbend retaining clips.
    3. Remove the battery and install a new CR2032 battery, observing polarity.
    4. Reassemble the sensor by following the above steps in reverse order.
    Женщина-диспетчер ПЦН
    Choosing a location for the sensor
    Mount the magnetically operated switch (1) to the fixed part of a structural element (e.g. a door frame), and then mount the magnet (2) to the moving part of the structural element (e.g. a door leaf or a window sash). The sensor can be mounted vertically or horizontally.
      DO NOT install the sensor outdoors, in places with high humidity, or at temperatures exceeding the operating temperature range (see "Specifications" table).
      Evaluating signal strength
      Check the quality of the connection between the sensor and the hub at the intended location of the sensor.

      There are two ways to evaluate the signal strength:

      1. In the Livicom app, on the sensor settings screen.
      2. With the help of the LED indication on the sensor. Insert a thin paper clip into the hole in the device enclosure (4) and press the binding mode button twice. Interpret the indication using the table below.
      Good signal The indicator blinks green 3 times
      Average signal The indicator blinks green 2 times
      Poor signal The indicator blinks green once
      No connection The indicator blinks red 4 times
      Sensor installation
      1. Open the enclosure of the magnetically operated switch (1): insert a flat-blade screwdriver into the hole between the lid and the base of the enclosure, and flip off the lid by turning the flat-blade screwdriver left or right.
      2. Fasten the base of the sensor enclosure at the selected location using a supplied mounting kit.
      3. Close the enclosure.
      4. Open the enclosure of the magnet (2): press one of the latches on the short side of the magnet using a flat-blade screwdriver and then pull the lid up while pressing the latch.
      5. Mount the magnet to the moving part of the structural element (e.g. a door leaf or a window sash).
      6. Place the center of the magnet near to the mark (5) on the magnetically operated switch.
      7. Close the magnet enclosure.
      Женщина-диспетчер ПЦН
      Checking the sensor operation
      Check the operation of the sensor after its installation. Make sure that the LED indication matches the information in the "LED indication" table below when you open and close the structural element (door or window).

      Enable full guard of the site through the Livicom app. Make sure that you see an alarm alert in the app when you open the guarded structural element.

      If you see an incorrect indication or do not receive the alert, then check:

      • whether the center of the magnet is placed near to the mark (4) on the magnetically operated switch;
      • whether the magnet comes near the magnetically operated switch (up to 10 mm) when you open and close the structural element (door or window).

      Contact technical support, if the magnet is placed correctly and you still observe an incorrect indication or do not receive the alerts.
      Sensor plate in the Livicom app
      Tap on the Devices button in the Livicom app. The sensor plate appears in the list on the Devices screen after the sensor has been bound to the hub.
      The sensor plate displays:

      1. The name of the sensor.
      2. Current state of the sensor (Open / Closed)
      3. Sensor icon for quick visual identification.
        Женщина-диспетчер ПЦН
        When the sensor detects the vibration, you will see on the sensor settings screen (if the guard is enabled):

        • The state of the sensor will change to Alarm! Intrusion detected,
        • Sensor icon will turn red.
            Женщина-диспетчер ПЦН
            Tap on the sensor plate to open the sensor settings screen.
            Sensor settings screen in the Livicom app
            The sensor settings screen displays:

            • Sensor description:
              • name;
              • appearance;
              • type and serial number;
              • current state:
                • Closed,
                • Open (if the guard is disabled),
                • Alarm! Closed (if the guard is enabled).
            • Operational parameters:
              • signal strength;
              • battery status.
            • Operational settings:
              • delay for entry / exit;
              • night guard;
              • installed on the front door.
            • Group. Tap on the group name to move the sensor to another group.
                Женщина-диспетчер ПЦН
                When the sensor detects an intrusion into the guarded site, you will see on the sensor settings screen:

                • The state of the sensor will change to Alarm! Intrusion detected.
                Женщина-диспетчер ПЦН
                Operational parameters
                • Radio signal strength between the sensor and the hub (no connection / poor / average / good):
                If there is no connection with the hub, check whether the hub is turned on. If the hub is off, turn the hub on and again check the signal strength on the sensor settings screen. Then check whether there are any objects obstructing radio signal (for example, metal objects or mirrors) between the hub and the sensor. Change the sensor installation location so that radio signal could pass between devices without obstructions.

                Check whether the sensor is installed within radio signal range of the hub. If the sensor is installed too far from the hub, move it to a new place where connection between the sensor and the hub will be restored.

                • Battery status (OK / low battery).
                If the battery runs out, you will receive the push notification. The notification will also be displayed in the event log in the app and on the sensor settings screen. Follow instructions to replace the battery
                  Operational settings
                  Only the owner of the site can change settings for the sensor. Make sure that the site guard is disabled and the hub is online.
                  • Delay for entry / exit - slide the switch to the right if the sensor is mounted in the entrance area of the site AND the site guard is controlled by the Livi RFID security control panel.

                  • Night guard - slide the switch to the right if the sensor should be switched to the guarding mode when the night guard is enabled.

                  • Installed on the front door - move the switcher to the left if you do not use a Livi RFID control panel to enable / disable the guard of the site (the switcher will turn grey). Move the switcher to the right if you use a Livi RFID control panel to enable / disable the guard of the site AND the Livi CSM opening sensor is installed on the front door of the site (the switcher will turn green). The setting "Installed on the front door" impacts the way the delay for entry / exit will be counted. If the front door of the site is protected with the Livi CSM opening sensor, then:
                    • the full guard will be enabled immediately after the user shuts the front door (even if the delay for exit is not over),
                    • the delay for entry countdown will start at the moment the user opens the front door.
                  Renaming the sensor
                  Only the owner of the site can rename the sensor. Make sure that the site guard is disabled and the hub is online before renaming.
                  • In the upper right corner of the settings screen tap on three dots ("Menu" button).
                  • Select Rename in the menu.
                  • Enter a new name and save it.
                  Женщина-диспетчер ПЦН
                  Maintenance
                  Keep the sensor free of dust and dirt. Replace the battery as soon as possible after you receive a low battery notification in the Livicom app.
                  Attention

                  Do not wipe the sensor with substances containing alcohol, acetone, gasoline and other active solvents

                  Deleting the sensor (unbinding from the hub)
                  Only the owner of the site can unbind the sensor from the hub. Make sure that the site guard is disabled and the hub is online before deleting the sensor.
                  There are two ways to unbind the sensor from the hub:

                  1. In the Livicom app, using the menu on the sensor settings screen.
                  2. Using the binding mode button. Insert a thin paper clip into the hole in the sensor enclosure (4), press the binding mode button and hold it until the sensor indicator starts blinking blue.
                  Женщина-диспетчер ПЦН
                  Specifications
                  Operating frequency 868 MHz
                  Guaranteed operating range in open areas up to 1 km
                  Radio channel power 20 mW
                  Sensing distance up to 10 mm
                  Current consumption in sleep mode 3 μA
                  Current consumption in operation mode up to 30 mA
                  Power source (3 V) battery CR2032
                  Battery life 2,5 years
                  Operating temperature range from 0 to +55 °C
                  Relative humidity no more than 80% at 25 °C
                  Magnetically operated switch dimensions 45 x 24 x 12 mm
                  Magnet dimensions 45 х 13 х 12 mm
                  Supply set
                  Livi CSM opening sensor 1
                  Mounting kit 1
                  Lithium battery CR2032 (3 V) 1
                  Protective film for the battery 1
                  Packaging 1
                  LED indication
                  Open The indicator blinks red once
                  Closed The indicator blinks green once
                  Binding mode The indicator blinks blue for 1 minute
                  Confirmation of successful binding The indicator blinks green 5 times
                  Warranty
                  The manufacturer LLC "NPP Stels" guarantees that the sensor meets AGNS.421453.001 TU technical requirements, provided that the consumer complies with the conditions of transportation, storage, installation and operation.

                  The warranty period is 5 years from the manufacturing date. The warranty does not apply to batteries.

                  The warranty does not cover the following cases:

                  1. Non-compliance with the intended operating conditions for the sensor;
                  2. Mechanical damage to the sensor;
                  3. Repairs to the sensor by a third party (a person or a company other than the Manufacturer).