Livicom Smart Home

Livi Key Fob control panel manual

Description
The Livi Key Fob control panel (hereafter referred to as the panel) is designed to enable/disable a security alarm system, to launch scripts and to send an alarm signal to the Livi Smart Hub (hereafter referred to as the hub).

The panel is designed as a key fob, which has 4 programmable buttons. By default the function of enabling the site's guard is assigned to the first button (2A).
Panel appearance
undefined undefined undefined
  1. LED indicator
  2. Buttons
  3. Retaining screw
  4. Battery
Женщина-диспетчер ПЦН
Binding the panel to the hub
The panel must be unpacked and allowed to reach room temperature for at least two hours before handling if it was transported or stored at low temperatures.
Only the owner of the site can bind the panel to the hub. Make sure that the site guard is disabled and the hub is online before binding.
Follow these steps to bind the panel to the hub:

1. Press the uppermost (2A) and lowest (2D) buttons on the panel and hold them until the indicator (1) starts blinking blue. The panel will be switched to the binding mode.
Женщина-диспетчер ПЦН
2. In the Livicom app, open the "Devices" screen. In the upper right corner of the screen tap "+" and select "Add Device".

The system compiles a list of radio devices available for binding within the range of the hub radio channel.

3. Select the panel from the list and check that its name and serial number in the app match the data on the panel enclosure.

4. Tap CONTINUE and follow on-screen instructions in the app to bind the panel to the hub.

The panel indicator will blink green 5 times after successful binding.
Женщина-диспетчер ПЦН
The panel switches to the binding mode only for 60 seconds. If you have not bound it to the hub within this period, press the uppermost (2A) and lowest (2D) buttons on the panel again and hold them until the indicator (1) starts blinking blue.
Replacing the battery
  1. Loosen the retaining screw.
  2. Open the panel enclosure: insert a flat screwdriver into the hole in the bottom of panel enclosure and push out the panel lid.
  3. Remove the battery (4) and install a new one, observing polarity.
  4. Close the panel enclosure and fasten the retaining screw.
Женщина-диспетчер ПЦН
Evaluating signal strength
Double-click on the lowest button (2D) of the panel and look at the panel indicator. Interpret the indication using the table below.
Good signal The indicator blinks green 3 times
Average signal The indicator blinks green twice
Poor signal The indicator blinks green once
No connection The indicator blinks red 4 times
Site guard enabling and disabling
By default settings press the button (2A) to enable full guard of the site. Make sure that the panel indicator blinks green once and the notification is sent to the Livicom app.

The Livicom system checks statuses of all security sensors when it is enabling the guard. If the system fails to switch some sensors into the guarding mode, then the panel indicator will blink yellow 3 times and the guard of the site won't be enabled. If you want to enable the full guard with the exception of some sensors (for example, if you intentionally left the window open for ventilation), then make two more attempts to enable the full guard. On the third attempt the site's full guard will be enabled, but some sensors will not perform guarding functions. The panel indicator will blink green once to confirm enabling the guard.

By default press the button (2B) to disable full guard of the site. Make sure that the panel indicator blinks green twice and the notification is sent to the Livicom app.

Contact technical support (mail to: support@livicom.ru) if you see an incorrect operation of the panel.
Panel plate in the Livicom app
Tap on the Devices button in the Livicom app. The panel plate appears in the list on the Devices screen after the panel has been bound to the hub.
The panel plate displays:

  1. The name of the panel.
  2. Panel icon for quick visual identification.
Женщина-диспетчер ПЦН
Tap on the panel plate to open the panel settings screen.
Panel settings screen in the Livicom app
Only the owner of the site can change settings for the panel. Make sure that the site guard is disabled and the hub is online if you are going to change the panel settings.
The panel settings screen displays:

  • Panel description:
    • name;
    • appearance;
    • type and serial number.
  • Battery status.
If the battery runs out, you will receive the push notification. The low battery notification will also be displayed in the event log in the app and on the panel settings screen. Follow instructions to replace the battery.

  • Functions that are assigned to the panel buttons.
The panel settings screen allows you to change the functions assigned to the panel buttons. To change the function, tap on the button line and select a new function from the list (see below).

  • Group. Tap on the group name to move the panel to another group.
Женщина-диспетчер ПЦН
The system automatically includes the list of functions available for assigning to the panel buttons:

  1. Enabling or disablingthe full guard of the site.
  2. Enabling or disabling the night guard of the site.
  3. Sending an alarm signal to the hub (Alarm button function).
  4. Enabling or disabling the guard of the group.
  5. Enabling or disabling an endpoint device.
    Turning on/off an endpoint device like Livi Relay, Livi Relay 12/24, Livi Socket, Livi Water Control leakage protection module, Livi Siren, Livi Roller Shutter curtain control module and Livi Light Control module.
  6. Launching on of the click-driven scripts.

The system will prompt you to select an action (on or off) after selecting the function. Select the action to return to the panel settings screen.

The function will be assigned to the panel button.
Женщина-диспетчер ПЦН
Renaming the panel
Only the owner of the site can rename the panel. Make sure that the site guard is disabled and the hub is online before renaming.
  • In the upper right corner of the settings screen tap on three dots ("Menu" button).
  • Select Rename in the menu.
  • Enter a new name and save it.
Женщина-диспетчер ПЦН
Maintenance
Keep the panel free of dust and dirt.
Attention

Do not wipe the panel with substances containing alcohol, acetone, gasoline and other active solvents
Deleting the sensor (unbinding from the hub)
Only the owner of the site can unbind the panel from the hub. Make sure that the site guard is disabled and the hub is online before deleting the panel
You can delete the panel from the hub using the menu on the panel settings screen.

If you need to forcefully delete the panel, press the uppermost (2A) and lowest (2D) buttons on the panel and hold them at least 10 sec (until the panel indicator starts blinking blue).
Женщина-диспетчер ПЦН
Specifications
Operating frequency 868 MHz
Guaranteed operating range in open areas up to 1000 m
Radio channel power 25 mW
Current consumption in operation mode up to 30 mA
Power source (3 V) ;Lithium battery CR2032
Operating temperature range from -20 to +55 °C
Relative humidity no more than 80% at 25 °C
Dimensions 61 x 35 x 13 mm
Supply set
Livi Key Fob control panel 1
Lithium battery CR2032 (3 V) 1
Passport 1
Packaging 1
LED Indication
A button on the panel is pressed The indicator blinks white once
Full guard is enabled The indicator blinks green once
Full guard is disabled The indicator blinks green twice
Night guard is enabled The indicator blinks blue once
Night guard is disabled The indicator blinks blue twice
Guard enabling error The indicator blinks yellow 3 times
Sending an alarm signal to the hub The indicator blinks red 5 times
Turning on an endpoint device The indicator blinks green once
Turning off an endpoint device The indicator blinks green twice
Command execution failure The indicator blinks red once
Binding mode The indicator blinks blue for 1 minute
Confirmation of successful binding The indicator blinks green 5 times
Warranty
The manufacturer LLC "NPP Stels" guarantees that the panel meets AGNS.421453.001 TU technical requirements, provided that the consumer complies with the conditions of transportation, storage, installation and operation.

The warranty period is 5 years from the manufacturing date. The warranty does not apply to batteries.

The warranty does not cover the following cases:

  1. Non-compliance with the intended operating conditions;
  2. Mechanical damage to the panel;
  3. Repairs to the panel by a third party (a person or a company other than the Manufacturer).