Livicom Smart Home

Scheduled scripts

Scheduled scripts allow you to set actions that will be performed repeatedly on a schedule
Only the site's owner and admins are allowed to create, edit and delete scripts. All users of the site can view script settings screens.
Create a new script
1. Tap on the «Scripts» in the naviation bar to open the «Scripts» screen

2. Tap on the «+» button located in the upper right corner of the screen.
The Scripts screen Livicom
3. Select the script type which you want to create: «Scheduled script».
Select script type Livicom
4. On the script settings screen, follow these steps:

  • Name the script. We recommend picking up a concise (up to 50 characters) name which is understandable for all users of the site.

  • Turn on or off the notifications about script launches. By default, the notifications are enabled.

  • Select all actions to be performed when the script is launched. Tap on the + ACTIONS button to select the actions (details are below).

  • Schedule the script launches.

  • Set the time period for which the actions should be performed. Tap on the + TIMER button to set the timer.
Create the scheduled script Livicom
Enable / disable push-notifications about the script launches:
  • Enable the notifications *
    Slide the switch to the right.
  • Disable the notifications
    Slide the switch to the left.
* You will receive the push-notification in the mobile app when the script is launched.
push-notification Livicom
The entries about the script launches are added to the event log even if the notifications are disabled.
Event log Livicom
Select actions that should be performed when the script is launched
  • Tap on the + ACTIONS button to select the actions to be performed when the script is launched.

The system automatically forms and displays the list of actions. The list includes enabling / disabling the full guard, the night guard of the site and the guard of the groups («Guard» section), turning on / off endpoint devices and device groups («Devices» section).

Endpoint devices are Livi Relay and Livi Relay 12/24, Livi Sockets, Livi Water Control units, Livi Sirens, Livi Roller Shutter units and Livi Light Control units.

  • Tick the devices, device groups and guarding modes that will affected by the script.

The script on the figure will use the Night guard for the action.

  • Tap on the arrow in the upper left corner of the screen to go back to the script settings screen.
Select actions for script Livicom
Up to 8 actions can be added to each script. The following endpoint devices do not turn on / off with the device group even if they are added to the group: Livi Relay, Livi Relay 12/24 and Livi Socket (if the Use as thermostat feature is enabled), Livi Roller Shutter and Livi Siren.
Specify the action that will be performed for each selected endpoint device or guarding mode:
  • The device, device group or guarding mode will be enabled when the script launches.
  • The device, device group or guarding mode will be disabled when the script launches.
  • Delete the device, device group or guarding mode from the script actions list.
The Night guard of the site will be enabled when the script on the figure is launched.

The «DELETE ALL» button allows you to empty the script actions list.
Create the scheduled script Livicom
You will not be able to save the script if you have not selected any actions and the notifications are disabled.
Set up the script launch schedule
  • Set the launch time of the script and select the days of the week on which the script will run repeatedly.

The selected week days have green backgrounds, unselected days are displayed on a white background.

  • Tap on the arrow in the upper left corner of the screen to go back to the script settings screen.
Date and time for scheduled script Livicom
    The figure shows that the script will launch at 10:00 pm on weekdays.
      The scheduled-script Livicom
      Set the script timer
      • Set the time period from 10 seconds to 24 hours. The timer will start counting when the user launches the script. The opposite action to that specified in the script will be performed for each selected endpoint device or guarding mode when the timer has expired.

      Exceptions: When the timer expires, the Livi Roller Shutter unit will not perform any actions (the curtains will remain in the position that is set in the script); the Livi Relay, Livi Relay 12/24 and Livi Socket will switch to maintain the desired temperature set on the device setting screen (if the Use as thermostat feature is enabled). The Livi Relay 12/24 with the preset pulse will be turned off when the pulse duration expires (set on the relay settings screen) and it will not do any actions when the timer ends. The Livi Siren will be silenced when the preset alarm duration expires ( set on the siren settings screen) and it will not do any actions when the timer ends.

      • Tap on the arrow in the upper left corner of the screen to save the timer and go back to the script settings screen.
      The timer for scheduled-script Livicom
      The night guard will be disabled in 9 hours after the script on the figure has been launched (even if the night guard had been enabled before the script was launched).
      New script Livicom
      If the script is configured the way you want, then tap on the «ADD» button (in the upper right corner) to save the script and go back to the script list.
      Scheduled scripts become active as soon as they are saved. The script will be launched automatically on schedule.
      If the user manually turns on / off the device involved in the script or reboots the hub, then the timer counting down in the running script will stop.

      If the hub firmware has been updated to version 1.11 and higher, then the timer counting down in the running script will continue after a programmatic reboot of the hub (reboot after a firmware update or by user command). But after a power boot of the hub (if the hub was de-energized), then the timer counting down in the running script will stop. The script will be launched again on the scheduled time after the power supply of the hub is restored.